Tube temperature range
5 °C to 65°C (40°F to 150°F)
Max Exposure Temp Power Off
85°C (185°F)
Power Options
W/m @10°C 9, 15, 25, 32 W/ft @50°F 3, 5, 8, 10
Voltage Range
100-277 Vac
T-Rating
T6 | T5
Minimum installation temperature
-40°C (-40°F)
TubeTrace with BSX™ Electrically Heated Tubing Bundles
TubeTrace, with “cut-to-length” BSX self-regulating heat tracing, is designed to provide freeze protection or temperature maintenance for tubing where no “steam out” o...
Available watt densities
W/m @10°C 8, 16, 33 W/ft @50°F 2.5, 5, 10
Supply Voltages
Supply Voltages
Max maintenance Temperature
65°C (150°F)
Max Exposure Temp Power Off
85°C (185°F)
Minimum installation temperature
-40°C (-40°F)
TubeTrace with FP™ Electrically Heated Tubing Bundles
TubeTrace, with “cut-to-length” FP constant watt heat tracing, is designed to provide freeze protection or temperature maintenance for tubing. The construction of F...
Available watt densities
16, 33, 49, 66 W/m @10°C 5, 10, 15, 20 W/ft @50°F
Supply Voltages
120 to 240 Vac
Maximum continuous exposure temperature Power-off
260°C (500°F)
Minimum installation temperature
-40°C (-40°F)
T-rating
T2 to T6
TubeTrace with HPT™ Electrically Heated Tubing Bundles
TubeTrace, with “cut-to-length” HPT power-limiting heat tracing, is designed to provide freeze protection or temperature maintenance for tubing where high temperature ...
Tube temperature range
5 °C to 150°C (40°F to 302°F)
Max Exposure Temp Power Off
250°C (482°F)
Power Options
W/m @10°C 10, 20, 30, 39, 49, 66 W/ft @50°F 3, 6, 9, 12, 15, 20
Voltage Range
100-277 Vac
T-Rating
T3 to T6
Minimum installation temperature
-40°C (-40°F)
TubeTrace with HTSX™ TubeTrace with HTSX™
TubeTrace, with “cut-to-length” HTSX self-regulating heat tracing, is designed to provide freeze protection or temperature maintenance for tubing where high temperatur...
Tube temperature range
5°C to 149°C (40°F to 300°F)
Max Exposure Temp Power Off
250°C (482°F)
Power Options
16, 33, 49, 66 W/m @10°C 5, 10, 15, 20 W/ft @50°F
Supply Voltages
100-120 or 208-277 Vac
Minimum installation temperature
-40°C (-40°F)
TubeTrace with VSX-HT™ Electrically Heated Tubing Bundles
TubeTrace, with “cut-to-length” VSX-HT self-regulating heat tracing, is designed to provide freeze protection or temperature maintenance for tubing where high tem...
Maintain temperature
5°C (40°F)
Minimum design ambient
-45°C (-50°F)
Max Exposure Temp
399°C (750°F)
Power Options
W/m @10°C 33 W/ft @50°F 10
Voltage Range
120 to 240 Vac
TubeTrace Type SEI/MEI — HT Electrically Heated Tubing Bundles
TubeTrace HT is a pre-engineered electric traced tube bundle for steam sample lines and impulse lines to pressure transmitters. TubeTrace HT will provide water freeze ...
Maintain temperature
5°C (40°F)
Minimum design ambient
-45°C (-50°F)
Max Exposure Temp
593°C (1100°F)
Power Options
W/m @10°C W/m @10°C 33 W/ft @50°F 10
W/ft @50°F 10
Voltage Range
120 to 240 Vac
TubeTrace Type SEI/MEI — HTX Electrically Heated Tubing Bundles
TubeTrace HT is a pre-engineered electric traced tube bundle for steam sample lines and impulse lines to pressure transmitters. TubeTrace HT will provide water freeze ...
Maintain temperature
5°C (40°F)
Minimum design ambient
-34°C (-30°F)
Max Exposure Temp
593°C (1100°F)
Power Options
W/m @10°C 16 W/ft @50°F 5
Voltage Range
120 to 240 Vac
TubeTrace Type SEI/MEI — HTX2 Electrically Heated Tubing Bundles
TubeTrace HTX2 is a pre-engineered electric traced tube bundle for steam sample lines and impulse lines to pressure transmitters. TubeTrace HTX2 will provide water fre...
Rated voltage
300 and 600 Vac
Max. maintenance temperature
500°C (932°F)
Max. continuous exposure temperature Power-off
600°C (1,112°F)
Max. watt density
up to 262 W/m (80 w/ft)
Minimum installation temperature
-40°C (-40°F)
TubeTrace with MIQ™ Electrically Heated Tubing Bundles
TubeTrace, with series resistance MI heat tracing, is designed to maintain high temperatures or provide freeze protection where high temperature exposure is possible. ...