Catalog
Power density options
9, 15, 25, 32 W / m at 10 ° C
3, 5, 8, 10 W / ft at 50 ° F
Supply voltage
100-120 or 208-277 VAC current
Maximum maintenance temperature
65°C (150°F)
Maximum temperature impact when power is off
85°C 185°F
Minimum installation temperature
51°C (-60°F)
Minimum bend radius
at -15 ° C (5 ° F) 10 mm (0.38 ")
at -60 ° C (-76 ° F) 32 mm (1.25 ")
Temperature class 1
10, 16, 26 W / m (3, 5, 8 W / ft)
T6
85 ° C (185 ° F)
33 W / m (10 W / ft)
T5
100°C (212°F)
BSX™ Self-regulating heating cable
BSX self-regulating heating cables, designed to protect against freezing and maintain operating temperature, provide protection against freezing and maintaining the wo...
Available watt densities
15 W/m @10°C 49 W/ft@50°F
Supply Voltages
100-120 or 208-240 Vac
Max maintenance Temperature
65°C (150°F)
Max Exposure Temp Power Off
85°C (185°F)
Minimum installation temperature
-51°C (-60°F)
Minimum bend radius
@ -15°C (5°F) 10 mm (0.38”) @ -60°C (-76°F) 32 mm (1.25”)
RSX™ 15-2 Self-Regulating Heating Cable
Freeze Protection or Process Temperature Maintenance RSX 15-2 self-regulating heating cable is designed for applications where the watt density requirements preclude t...
Available watt densities
10, 20, 30, 39, 49, 66 W/m @10°C 3, 6, 9, 12, 15, 20 W/ft @50°F
Supply Voltages
100-120 or 208-277 Vac
Max maintenance Temperature
150°C (302°F)
Max Exposure Temp Intermittent power-on or off
250°C (482°F)
Continuous power-off
204°C (400°F)
Minimum installation temperature
-51°C (-60°F)
Minimum bend radius
@ -15°C (5°F) 10 mm (0.38”) @ -60°C (-76°F) 32 mm (1.25”)
HTSX™ Self-Regulating Heating Cable
Process Temperature Maintenance or Freeze Protection HTSX self-regulating heating cables are designed specifically for process temperature maintenance or freeze protec...
Available watt densities
16, 33, 49, 66 W/m @10°C 5, 10, 15, 20 W/ft @50°F
Supply Voltages
100-120 or 208-277 Vac
Max maintenance Temperature
149°C (300°F)
Max Exposure Temp Intermittent power-on
232°C (450°F)
Continuous power-off
204°C (400°F)
VSX™ Self-Regulating Heating Cable
Process Temperature Maintenance or Freeze Protection High performance VSX self-regulating heating cables are designed specifically for process temperature maintenance ...
Available watt densities
16, 33, 49, 66 W/m @10°C 5, 10, 15, 20 W/ft @50°F
Supply Voltages
100-120 or 208-277 Vac
Max maintenance Temperature
200°C (392°F)
Intermittent power-off
250°C (482°F)
Based on Stabilized Design
T2 to T6
VSX-HT™ Self-Regulating Heating Cable
High performance VSX-HT self-regulating heating cables are designed specifically for process temperature maintenance or freeze protection applications where high maint...
Available watt densities
16, 33, 49, 66 W/m @10°C 5, 10, 15, 20 W/ft @50°F
Supply Voltages
Supply Voltages
Max maintenance Temperature
HPT 5 210°C (410°F) HPT 10 190°C (374°F) HPT 15 175°C (347°F) HPT 20 150°C (302°F)
Maximum continuous exposure temperature Power-off
260°C (500°F)
Minimum installation temperature
-60°F (-51°C)
HPT™ Power-Limiting Heating Cable
High performance HPT power-limiting heating cables are designed specifically for process temperature maintenance or freeze protection where high maintain temperatures ...
Available watt densities
8, 16, 33 W/m @10°C 2.5, 5, 10 W/ft @50°F
Supply Voltages
120/240 Vac
Max maintenance Temperature
65°C (150°F)
Max Exposure Temp Power Off
85°C (185°F)
T-rating
T3 to T6
FP™ Parallel Constant Watt Heating Cable
Freeze Protection or Process Temperature Maintenance FP parallel resistance constant watt heating cables are designed to provide freeze protection or process temperatu...
Rated voltage
up to 600 Vac
Max. maintenance temperature
101°C (215°F)
Max. continuous exposure temperature Power-off
232°C (450°F)
Minimum installation temperature
-51°C (-60°F)
TEK™ Series Constant Watt Heating Cable
Long Line Temperature Maintenance or Freeze Protection TEK series resistance constant watt heating cables are used where circuit lengths exceed the limitations of para...
Rated voltage
up to 600 Vac
Max. maintenance temperature
204°C (400°F)
Max. continuous exposure temperature Power-off
260°C (500°F)
Minimum installation temperature
-51°C (-60°F)
HTEK™ Series Constant Watt Heating Cable
High performance HTEK series resistance constant watt heating cables are used where circuit lengths exceed the limitations of parallel resistance heating cables and hi...
Rated voltage
300 and 600 Vac
Max. maintenance temperature
500°C (932°F)
Max. continuous exposure temperature Power-off
600°C (1,112°F)
Max. watt density
up to 262 W/m (80 w/ft)
Minimum installation temperature
-60°C (-76°F)
MIQ™ Series Constant Watt Heating Cable
MIQ high performance mineral insulated heating cables are used extensively for high temperature maintenance, high temperature exposure and/or high watt density applica...